86 independent product pages with Key Phrase / SEO Title / H1 / Slug / Meta / Image alt and body rules.
Key phrases are exclusive to this series and do not reuse any key phrase from the plating, chrome or electrolysis series pages.
{Key Phrase} | {current} {voltage} short keyword; H1 is a full long description containing the key phrase.<strong> appears exactly 3 times.*All parameters subject to change, custom designs available upon request.Related Models: links to the adjacent current-rating models with the corresponding Key Phrase as anchor text.The Standard Electrocoagulation Rectifier from Gaohui Rectifier provides 50A at 36V. This Standard Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Standard Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–50A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Electro-Catalytic Oxidation Rectifier from Gaohui Rectifier delivers 50A at 36V. Engineers choose this Electro-Catalytic Oxidation Rectifier when dosing repeatability matters across shifts. Moreover, the Electro-Catalytic Oxidation Rectifier pairs naturally with electro-catalytic oxidation cell stacks.
For instance, chemical plants treat spent solvent rinse water through DSA anode cells. The rectifier supplies a steady DC so hydroxyl radicals form at a constant rate. In practice, a batch reactor runs several cycles per day. Hence, operators dial in a fixed current that matches the organic load. Thus, COD drops predictably batch after batch.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–50A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Electro-Fenton Rectifier outputs 50A at 36V. Plant operators rely on this Electro-Fenton Rectifier to keep treatment current flat all day. Therefore, the Electro-Fenton Rectifier fits electro-fenton lines from pilot to production.
Moreover, landfill operators pair fenton cells with biological treatment to break down micropollutants. The rectifier holds current steady so hydroxyl radical production stays consistent. In practice, leachate temperature shifts with season. Consequently, operators fine-tune setpoints twice a year. Thus, the downstream activated sludge plant sees a stable feed.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–50A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-fenton cells |
| Typical Application | Electro-Fenton Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Electro-Descaling Rectifier from Gaohui Rectifier provides 30A at 36V. This Electro-Descaling Rectifier holds cell current steady through long shifts. Furthermore, the Electro-Descaling Rectifier suits electro-descaling cells and electrode banks.
Cells in electro-descaling lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady scale removal. In practice, a plant treating cooling water circuits around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–30A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-descaling cells |
| Typical Application | Electro-Descaling |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Automatic Periodic Reversal Rectifier from Gaohui Rectifier delivers 50A at 1000V. Engineers choose this Automatic Periodic Reversal Rectifier when dosing repeatability matters across shifts. Moreover, the Automatic Periodic Reversal Rectifier pairs naturally with periodic reversal cell stacks.
For example, electrowinning plants reverse polarity to strip cathode deposits automatically. The rectifier toggles direction on a set schedule so no manual scraping is needed. In practice, a refinery runs 15 minute cycles around the clock. Hence, operators recover metal without stopping the line. Thus, labor cost drops and uptime rises.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–50A adjustable |
| DC Output Voltage | 0–1000V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Electrodialysis Rectifier outputs 100A at 100V. Plant operators rely on this Electrodialysis Rectifier to keep treatment current flat all day. Therefore, the Electrodialysis Rectifier fits electrodialysis lines from pilot to production.
Moreover, food and beverage plants use electrodialysis to demineralize whey and sugar solutions. The rectifier holds voltage steady so membrane pairs do not overheat. In practice, a dairy runs its whey processing line in batches. Consequently, operators set a fixed voltage for each batch. Thus, mineral removal stays consistent between runs.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–100V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrodialysis stacks |
| Typical Application | Electrodialysis Stacks |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Single Pulse Electrocoagulation Rectifier from Gaohui Rectifier provides 100A at 500V. This Single Pulse Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Single Pulse Electrocoagulation Rectifier suits pulse electrocoagulation cells and electrode banks.
Cells in pulse electrocoagulation lines run for hours at a time. In addition, the rectifier delivers controlled pulses that sharpen floc formation. In practice, a plant treating oily wastewater around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–500V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Single pulse DC output for coagulation cells |
| Typical Application | Pulse Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Single Pulse Electro-Catalytic Rectifier from Gaohui Rectifier delivers 400A at 50V. Engineers choose this Single Pulse Electro-Catalytic Rectifier when dosing repeatability matters across shifts. Moreover, the Single Pulse Electro-Catalytic Rectifier pairs naturally with pulse electro-catalytic cell stacks.
For example, textile dye houses decolorize effluent with pulsed oxidation cells. The rectifier modulates current so hydroxyl radical bursts attack chromophore groups. In practice, a finishing mill switches dye batches several times a day. Therefore, operators tune pulse width to the specific dye class. As a result, color removal stays above ninety percent.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–400A adjustable |
| DC Output Voltage | 0–50V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Single pulse DC output for oxidation cells |
| Typical Application | Pulse Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Sodium Hypochlorite DC Rectifier outputs 200A at 24V. Plant operators rely on this Sodium Hypochlorite DC Rectifier to keep treatment current flat all day. Therefore, the Sodium Hypochlorite DC Rectifier fits sodium hypochlorite lines from pilot to production.
In addition, swimming pool operators and cooling tower users generate one percent hypochlorite on site. The rectifier holds current so chlorine concentration stays in spec. In practice, a leisure center runs its pool system daily. Hence, operators never handle concentrated bleach drums. Thus, storage and spill risks drop to near zero.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–200A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Compact Electrocoagulation Rectifier from Gaohui Rectifier provides 10A at 300V. This Compact Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Compact Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–10A adjustable |
| DC Output Voltage | 0–300V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Electrodialysis Reversing Rectifier from Gaohui Rectifier delivers 20A at 18V. Engineers choose this Electrodialysis Reversing Rectifier when dosing repeatability matters across shifts. Moreover, the Electrodialysis Reversing Rectifier pairs naturally with electrodialysis cell stacks.
For instance, brackish water treatment plants run electrodialysis stacks to produce irrigation quality water. The rectifier supplies a flat DC so ion migration stays linear. In practice, an agricultural operation runs its wells year round. Therefore, operators match current to the salinity reading. Hence, recovery rate stays above seventy percent.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–20A adjustable |
| DC Output Voltage | 0–18V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrodialysis stacks |
| Typical Application | Electrodialysis Stacks |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Pulse Electrocoagulation Rectifier outputs 30A at 500V. Plant operators rely on this Pulse Electrocoagulation Rectifier to keep treatment current flat all day. Therefore, the Pulse Electrocoagulation Rectifier fits pulse electrocoagulation lines from pilot to production.
Moreover, produced water from oil and gas operations gets polished with pulse electrocoagulation. The pulsed waveform strips dispersed oil droplets from the brine. In practice, a facility runs its treatment train 24 hours a day. Consequently, operators set fixed pulse parameters after commissioning. Thus, the downstream filter sees a stable feed.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–30A adjustable |
| DC Output Voltage | 0–500V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Single pulse DC output for coagulation cells |
| Typical Application | Pulse Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Sodium Hypochlorite Rectifier from Gaohui Rectifier provides 60A at 16V. This Sodium Hypochlorite Rectifier holds cell current steady through long shifts. Furthermore, the Sodium Hypochlorite Rectifier suits sodium hypochlorite cells and electrode banks.
Cells in sodium hypochlorite generation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for steady chlorine yield. In practice, a plant generating hypochlorite on site around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–60A adjustable |
| DC Output Voltage | 0–16V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Compact Air Cooled Electro-Descaling Rectifier from Gaohui Rectifier delivers 10A at 36V. Engineers choose this Compact Air Cooled Electro-Descaling Rectifier when dosing repeatability matters across shifts. Moreover, the Compact Air Cooled Electro-Descaling Rectifier pairs naturally with electro-descaling cell stacks.
For instance, cooling tower operators run descaling cells to avoid acid wash-downs. The rectifier feeds the electrode array so calcium carbonate stays dissolved. In practice, a commercial building runs its tower loop year round. Hence, operators check the cell monthly instead of acid cleaning quarterly. Thus, maintenance crews save a full day each quarter.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–10A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-descaling cells |
| Typical Application | Electro-Descaling |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Small Scale Electro-Descaling Rectifier outputs 10A at 36V. Plant operators rely on this Small Scale Electro-Descaling Rectifier to keep treatment current flat all day. Therefore, the Small Scale Electro-Descaling Rectifier fits electro-descaling lines from pilot to production.
In addition, breweries and dairies plate heat exchangers foul with milk stone and beer stone. The descaling rectifier drives titanium electrodes to keep surfaces clean. In practice, a dairy runs its CIP loop several times a day. Therefore, operators leave the rectifier on during production hours. As a result, heat transfer efficiency stays near factory new.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–10A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-descaling cells |
| Typical Application | Electro-Descaling |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Single Pulse Electrocoagulation Rectifier from Gaohui Rectifier provides 80A at 500V. This Air Cooled Single Pulse Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Single Pulse Electrocoagulation Rectifier suits pulse electrocoagulation cells and electrode banks.
Cells in pulse electrocoagulation lines run for hours at a time. In addition, the rectifier delivers controlled pulses that sharpen floc formation. In practice, a plant treating oily wastewater around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–80A adjustable |
| DC Output Voltage | 0–500V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Single pulse DC output for coagulation cells |
| Typical Application | Pulse Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Sodium Hypochlorite Rectifier from Gaohui Rectifier delivers 100A at 14V. Engineers choose this Air Cooled Sodium Hypochlorite Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Sodium Hypochlorite Rectifier pairs naturally with sodium hypochlorite cell stacks.
For example, municipal water plants generate dilute hypochlorite on site instead of delivering chlorine gas. The rectifier drives brine electrolysis cells at a constant current. In practice, a treatment plant doses disinfection around the clock. Therefore, operators adjust output to match demand curves. As a result, chemical delivery trucks stop coming weekly.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–14V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Compact Pulse Electrocoagulation Rectifier outputs 100A at 36V. Plant operators rely on this Air Cooled Compact Pulse Electrocoagulation Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Compact Pulse Electrocoagulation Rectifier fits pulse electrocoagulation lines from pilot to production.
Moreover, produced water from oil and gas operations gets polished with pulse electrocoagulation. The pulsed waveform strips dispersed oil droplets from the brine. In practice, a facility runs its treatment train 24 hours a day. Consequently, operators set fixed pulse parameters after commissioning. Thus, the downstream filter sees a stable feed.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Single pulse DC output for coagulation cells |
| Typical Application | Pulse Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Automatic Periodic Reversal Rectifier from Gaohui Rectifier provides 100A at 200V. This Air Cooled Automatic Periodic Reversal Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Automatic Periodic Reversal Rectifier suits periodic reversal cells and electrode banks.
Cells in periodic reversal lines run for hours at a time. Besides, the rectifier alternates polarity to clear electrode surfaces and hold treatment steady. In practice, a plant running reversal cells around the clock. Therefore, operators repeat the same setting from the first cell to the last. Consequently, operators set a current limit below rated output for lighter dosing.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–200V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Electrodialysis Automatic Reversal Rectifier from Gaohui Rectifier delivers 100A at 300V. Engineers choose this Electrodialysis Automatic Reversal Rectifier when dosing repeatability matters across shifts. Moreover, the Electrodialysis Automatic Reversal Rectifier pairs naturally with electrodialysis cell stacks.
For instance, brackish water treatment plants run electrodialysis stacks to produce irrigation quality water. The rectifier supplies a flat DC so ion migration stays linear. In practice, an agricultural operation runs its wells year round. Therefore, operators match current to the salinity reading. Hence, recovery rate stays above seventy percent.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–300V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrodialysis stacks |
| Typical Application | Electrodialysis Stacks |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Cooling Circuit Electro-Descaling Rectifier outputs 120A at 30V. Plant operators rely on this Cooling Circuit Electro-Descaling Rectifier to keep treatment current flat all day. Therefore, the Cooling Circuit Electro-Descaling Rectifier fits electro-descaling lines from pilot to production.
In addition, breweries and dairies plate heat exchangers foul with milk stone and beer stone. The descaling rectifier drives titanium electrodes to keep surfaces clean. In practice, a dairy runs its CIP loop several times a day. Therefore, operators leave the rectifier on during production hours. As a result, heat transfer efficiency stays near factory new.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–120A adjustable |
| DC Output Voltage | 0–30V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-descaling cells |
| Typical Application | Electro-Descaling |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Electro-Descaling Rectifier from Gaohui Rectifier provides 120A at 36V. This Air Cooled Electro-Descaling Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Electro-Descaling Rectifier suits electro-descaling cells and electrode banks.
Cells in electro-descaling lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady scale removal. In practice, a plant treating cooling water circuits around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–120A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-descaling cells |
| Typical Application | Electro-Descaling |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Electro-Catalytic Rectifier from Gaohui Rectifier delivers 150A at 30V. Engineers choose this Air Cooled Electro-Catalytic Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Electro-Catalytic Rectifier pairs naturally with electro-catalytic cell stacks.
For instance, pharmaceutical plants treat process wastewater through catalytic oxidation cells. The rectifier supplies a flat current so pharmaceutical residues break down completely. In practice, a batch plant generates variable effluent throughout the day. Therefore, operators leave the rectifier on a fixed setpoint. Hence, the municipal sewer sees consistent COD loads.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–150A adjustable |
| DC Output Voltage | 0–30V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Dedicated Sodium Hypochlorite Rectifier outputs 150A at 36V. Plant operators rely on this Air Cooled Dedicated Sodium Hypochlorite Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Dedicated Sodium Hypochlorite Rectifier fits sodium hypochlorite lines from pilot to production.
In addition, swimming pool operators and cooling tower users generate one percent hypochlorite on site. The rectifier holds current so chlorine concentration stays in spec. In practice, a leisure center runs its pool system daily. Hence, operators never handle concentrated bleach drums. Thus, storage and spill risks drop to near zero.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–150A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The High Voltage Single Pulse Electrocoagulation Rectifier from Gaohui Rectifier provides 150A at 500V. This High Voltage Single Pulse Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the High Voltage Single Pulse Electrocoagulation Rectifier suits pulse electrocoagulation cells and electrode banks.
Cells in pulse electrocoagulation lines run for hours at a time. In addition, the rectifier delivers controlled pulses that sharpen floc formation. In practice, a plant treating oily wastewater around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–150A adjustable |
| DC Output Voltage | 0–500V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Single pulse DC output for coagulation cells |
| Typical Application | Pulse Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Dedicated Air Cooled Sodium Hypochlorite Rectifier from Gaohui Rectifier delivers 160A at 36V. Engineers choose this Dedicated Air Cooled Sodium Hypochlorite Rectifier when dosing repeatability matters across shifts. Moreover, the Dedicated Air Cooled Sodium Hypochlorite Rectifier pairs naturally with sodium hypochlorite cell stacks.
For example, municipal water plants generate dilute hypochlorite on site instead of delivering chlorine gas. The rectifier drives brine electrolysis cells at a constant current. In practice, a treatment plant doses disinfection around the clock. Therefore, operators adjust output to match demand curves. As a result, chemical delivery trucks stop coming weekly.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–160A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Electrocoagulation Rectifier outputs 200A at 24V. Plant operators rely on this Air Cooled Electrocoagulation Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Electrocoagulation Rectifier fits electrocoagulation lines from pilot to production.
Moreover, food and beverage plants treat wash water through coagulation cells to remove fats and solids. The rectifier holds current steady so the floc blanket does not collapse between batches. In practice, a dairy runs its CIP recovery loop around the clock. Consequently, operators adjust dosing once at start-up and leave it. Thus, chemical costs drop sharply compared with dosing only.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–200A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Electro-Catalytic Oxidation Rectifier from Gaohui Rectifier provides 250A at 120V. This Air Cooled Electro-Catalytic Oxidation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Electro-Catalytic Oxidation Rectifier suits electro-catalytic oxidation cells and electrode banks.
Cells in electro-catalytic oxidation lines run for hours at a time. Therefore, the rectifier holds the current inside a narrow band for complete pollutant breakdown. In practice, a plant treating refractory organics around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–250A adjustable |
| DC Output Voltage | 0–120V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Automatic Polarity Reversing Electro-Catalytic Rectifier from Gaohui Rectifier delivers 300A at ±12V. Engineers choose this Automatic Polarity Reversing Electro-Catalytic Rectifier when dosing repeatability matters across shifts. Moreover, the Automatic Polarity Reversing Electro-Catalytic Rectifier pairs naturally with electro-catalytic cell stacks.
For instance, pharmaceutical plants treat process wastewater through catalytic oxidation cells. The rectifier supplies a flat current so pharmaceutical residues break down completely. In practice, a batch plant generates variable effluent throughout the day. Therefore, operators leave the rectifier on a fixed setpoint. Hence, the municipal sewer sees consistent COD loads.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–300A adjustable |
| DC Output Voltage | 0–±12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Dedicated Electro-Descaling Rectifier outputs 300A at 36V. Plant operators rely on this Air Cooled Dedicated Electro-Descaling Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Dedicated Electro-Descaling Rectifier fits electro-descaling lines from pilot to production.
In addition, breweries and dairies plate heat exchangers foul with milk stone and beer stone. The descaling rectifier drives titanium electrodes to keep surfaces clean. In practice, a dairy runs its CIP loop several times a day. Therefore, operators leave the rectifier on during production hours. As a result, heat transfer efficiency stays near factory new.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–300A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-descaling cells |
| Typical Application | Electro-Descaling |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Phosphorus Removal Rectifier from Gaohui Rectifier provides 300A at 220V. This Air Cooled Phosphorus Removal Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Phosphorus Removal Rectifier suits phosphorus removal cells and electrode banks.
Cells in phosphorus removal lines run for hours at a time. In addition, the rectifier holds the current inside a narrow band for steady dosing. In practice, a plant treating sewage effluent around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–300A adjustable |
| DC Output Voltage | 0–220V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for phosphorus removal cells |
| Typical Application | Phosphorus Removal Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Sodium Hypochlorite Automatic Reversal Rectifier from Gaohui Rectifier delivers 360A at 80V. Engineers choose this Air Cooled Sodium Hypochlorite Automatic Reversal Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Sodium Hypochlorite Automatic Reversal Rectifier pairs naturally with sodium hypochlorite cell stacks.
For example, municipal water plants generate dilute hypochlorite on site instead of delivering chlorine gas. The rectifier drives brine electrolysis cells at a constant current. In practice, a treatment plant doses disinfection around the clock. Therefore, operators adjust output to match demand curves. As a result, chemical delivery trucks stop coming weekly.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–360A adjustable |
| DC Output Voltage | 0–80V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the High Current Air Cooled Sodium Hypochlorite Rectifier outputs 380A at 80V. Plant operators rely on this High Current Air Cooled Sodium Hypochlorite Rectifier to keep treatment current flat all day. Therefore, the High Current Air Cooled Sodium Hypochlorite Rectifier fits sodium hypochlorite lines from pilot to production.
In addition, swimming pool operators and cooling tower users generate one percent hypochlorite on site. The rectifier holds current so chlorine concentration stays in spec. In practice, a leisure center runs its pool system daily. Hence, operators never handle concentrated bleach drums. Thus, storage and spill risks drop to near zero.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–380A adjustable |
| DC Output Voltage | 0–80V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Dual Output Electro-Catalytic DC Rectifier from Gaohui Rectifier provides 400A at 10V. This Air Cooled Dual Output Electro-Catalytic DC Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Dual Output Electro-Catalytic DC Rectifier suits electro-catalytic cells and electrode banks.
Cells in electro-catalytic treatment lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady reaction control. In practice, a plant treating industrial effluent around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–400A adjustable |
| DC Output Voltage | 0–10V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled High Current Electro-Catalytic Rectifier from Gaohui Rectifier delivers 500A at 12V. Engineers choose this Air Cooled High Current Electro-Catalytic Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled High Current Electro-Catalytic Rectifier pairs naturally with electro-catalytic cell stacks.
For instance, pharmaceutical plants treat process wastewater through catalytic oxidation cells. The rectifier supplies a flat current so pharmaceutical residues break down completely. In practice, a batch plant generates variable effluent throughout the day. Therefore, operators leave the rectifier on a fixed setpoint. Hence, the municipal sewer sees consistent COD loads.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Electro-Flotation Rectifier outputs 500A at 12V. Plant operators rely on this Air Cooled Electro-Flotation Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Electro-Flotation Rectifier fits electro-flotation lines from pilot to production.
In addition, oil refineries use induced gas flotation assisted by electro-flotation. The rectifier holds current steady so bubble density stays uniform. In practice, a refinery treats produced water 24 hours a day. Consequently, operators adjust dosing after each wash batch. Therefore, oil carry-over stays below spec.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-flotation cells |
| Typical Application | Electro-Flotation Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Medium Duty Electrocoagulation Rectifier from Gaohui Rectifier provides 500A at 12V. This Medium Duty Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Medium Duty Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled High Current Electrocoagulation Rectifier from Gaohui Rectifier delivers 500A at 18V. Engineers choose this Air Cooled High Current Electrocoagulation Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled High Current Electrocoagulation Rectifier pairs naturally with electrocoagulation cell stacks.
For example, metal finishing shops rely on electrocoagulation to strip oils from rinse water. The rectifier feeds the cell bank with a flat current so flocs form evenly across every plate. In practice, a job shop processes several batches each shift. Therefore, operators return to the same setpoint after each batch. Hence, effluent quality stays within permit limits.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–18V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Continuous Electrocoagulation Rectifier outputs 500A at 24V. Plant operators rely on this Air Cooled Continuous Electrocoagulation Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Continuous Electrocoagulation Rectifier fits electrocoagulation lines from pilot to production.
Moreover, food and beverage plants treat wash water through coagulation cells to remove fats and solids. The rectifier holds current steady so the floc blanket does not collapse between batches. In practice, a dairy runs its CIP recovery loop around the clock. Consequently, operators adjust dosing once at start-up and leave it. Thus, chemical costs drop sharply compared with dosing only.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Multi-Cabinet Electro-Catalytic Rectifier from Gaohui Rectifier provides 500A at 26V. This Multi-Cabinet Electro-Catalytic Rectifier holds cell current steady through long shifts. Furthermore, the Multi-Cabinet Electro-Catalytic Rectifier suits electro-catalytic cells and electrode banks.
Cells in electro-catalytic treatment lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady reaction control. In practice, a plant treating industrial effluent around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–26V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Pulse Automatic Reversal Rectifier from Gaohui Rectifier delivers 500A at 48V. Engineers choose this Air Cooled Pulse Automatic Reversal Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Pulse Automatic Reversal Rectifier pairs naturally with periodic reversal cell stacks.
For example, electrowinning plants reverse polarity to strip cathode deposits automatically. The rectifier toggles direction on a set schedule so no manual scraping is needed. In practice, a refinery runs 15 minute cycles around the clock. Hence, operators recover metal without stopping the line. Thus, labor cost drops and uptime rises.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–48V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled High Output Electrocoagulation Rectifier outputs 500A at 50V. Plant operators rely on this Air Cooled High Output Electrocoagulation Rectifier to keep treatment current flat all day. Therefore, the Air Cooled High Output Electrocoagulation Rectifier fits electrocoagulation lines from pilot to production.
Moreover, food and beverage plants treat wash water through coagulation cells to remove fats and solids. The rectifier holds current steady so the floc blanket does not collapse between batches. In practice, a dairy runs its CIP recovery loop around the clock. Consequently, operators adjust dosing once at start-up and leave it. Thus, chemical costs drop sharply compared with dosing only.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–50V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Production Electrocoagulation Rectifier from Gaohui Rectifier provides 600A at 15V. This Air Cooled Production Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Production Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–600A adjustable |
| DC Output Voltage | 0–15V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Heavy Duty Electro-Catalytic Rectifier from Gaohui Rectifier delivers 750A at 24V. Engineers choose this Air Cooled Heavy Duty Electro-Catalytic Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Heavy Duty Electro-Catalytic Rectifier pairs naturally with electro-catalytic cell stacks.
For instance, pharmaceutical plants treat process wastewater through catalytic oxidation cells. The rectifier supplies a flat current so pharmaceutical residues break down completely. In practice, a batch plant generates variable effluent throughout the day. Therefore, operators leave the rectifier on a fixed setpoint. Hence, the municipal sewer sees consistent COD loads.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–750A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Sodium Hypochlorite DC Rectifier outputs 800A at 36V. Plant operators rely on this Air Cooled Sodium Hypochlorite DC Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Sodium Hypochlorite DC Rectifier fits sodium hypochlorite lines from pilot to production.
In addition, swimming pool operators and cooling tower users generate one percent hypochlorite on site. The rectifier holds current so chlorine concentration stays in spec. In practice, a leisure center runs its pool system daily. Hence, operators never handle concentrated bleach drums. Thus, storage and spill risks drop to near zero.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–800A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Periodic Reversal Rectifier from Gaohui Rectifier provides 1000A at 10V. This Air Cooled Periodic Reversal Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Periodic Reversal Rectifier suits periodic reversal cells and electrode banks.
Cells in periodic reversal lines run for hours at a time. Besides, the rectifier alternates polarity to clear electrode surfaces and hold treatment steady. In practice, a plant running reversal cells around the clock. Therefore, operators repeat the same setting from the first cell to the last. Consequently, operators set a current limit below rated output for lighter dosing.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–1000A adjustable |
| DC Output Voltage | 0–10V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Electro-Fenton Rectifier from Gaohui Rectifier delivers 1000A at 18V. Engineers choose this Air Cooled Electro-Fenton Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Electro-Fenton Rectifier pairs naturally with electro-fenton cell stacks.
For example, dye houses use electro-fenton to decolorize textile effluent before discharge. The rectifier drives the iron electrode so Fe2+ regenerates continuously. In practice, a finishing mill runs its dye house effluent through the cell nonstop. Therefore, operators maintain a fixed current that matches the dye load. As a result, color comes well below permit limits.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–1000A adjustable |
| DC Output Voltage | 0–18V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-fenton cells |
| Typical Application | Electro-Fenton Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Electro-Catalytic Oxidation Drive Rectifier outputs 1000A at 24V. Plant operators rely on this Air Cooled Electro-Catalytic Oxidation Drive Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Electro-Catalytic Oxidation Drive Rectifier fits electro-catalytic oxidation lines from pilot to production.
Besides, landfill leachate treatment plants use oxidation cells to break down recalcitrant COD. The rectifier holds output flat despite swings in feed strength. In practice, leachate quality varies with weather and season. Therefore, operators tune current once and let the rectifier hold it. Consequently, downstream polishing loads stay manageable.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–1000A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled High Current Pulse Electrocoagulation Rectifier from Gaohui Rectifier provides 1000A at 24V. This Air Cooled High Current Pulse Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled High Current Pulse Electrocoagulation Rectifier suits pulse electrocoagulation cells and electrode banks.
Cells in pulse electrocoagulation lines run for hours at a time. In addition, the rectifier delivers controlled pulses that sharpen floc formation. In practice, a plant treating oily wastewater around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–1000A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Single pulse DC output for coagulation cells |
| Typical Application | Pulse Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Large Capacity Electrocoagulation Rectifier from Gaohui Rectifier delivers 1200A at 24V. Engineers choose this Air Cooled Large Capacity Electrocoagulation Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Large Capacity Electrocoagulation Rectifier pairs naturally with electrocoagulation cell stacks.
For example, metal finishing shops rely on electrocoagulation to strip oils from rinse water. The rectifier feeds the cell bank with a flat current so flocs form evenly across every plate. In practice, a job shop processes several batches each shift. Therefore, operators return to the same setpoint after each batch. Hence, effluent quality stays within permit limits.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–1200A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Dedicated Electro-Catalytic Rectifier outputs 1500A at 15V. Plant operators rely on this Air Cooled Dedicated Electro-Catalytic Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Dedicated Electro-Catalytic Rectifier fits electro-catalytic lines from pilot to production.
Moreover, pulp and paper mills use catalytic treatment to remove color from bleach plant effluent. The rectifier holds voltage steady across the electrode array. In practice, a mill runs its paper machine 24 hours a day. Consequently, operators tune current once after start-up. Thus, discharge color stays below regulatory limits year round.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–1500A adjustable |
| DC Output Voltage | 0–15V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Dedicated Electrocoagulation Rectifier from Gaohui Rectifier provides 1500A at 24V. This Air Cooled Dedicated Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Dedicated Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–1500A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Automatic Reversal Rectifier from Gaohui Rectifier delivers 2000A at 10V. Engineers choose this Air Cooled Automatic Reversal Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Automatic Reversal Rectifier pairs naturally with periodic reversal cell stacks.
For example, electrowinning plants reverse polarity to strip cathode deposits automatically. The rectifier toggles direction on a set schedule so no manual scraping is needed. In practice, a refinery runs 15 minute cycles around the clock. Hence, operators recover metal without stopping the line. Thus, labor cost drops and uptime rises.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–2000A adjustable |
| DC Output Voltage | 0–10V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Bulk Electrocoagulation Rectifier outputs 2000A at 24V. Plant operators rely on this Air Cooled Bulk Electrocoagulation Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Bulk Electrocoagulation Rectifier fits electrocoagulation lines from pilot to production.
Moreover, food and beverage plants treat wash water through coagulation cells to remove fats and solids. The rectifier holds current steady so the floc blanket does not collapse between batches. In practice, a dairy runs its CIP recovery loop around the clock. Consequently, operators adjust dosing once at start-up and leave it. Thus, chemical costs drop sharply compared with dosing only.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–2000A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Special Purpose Electro-Descaling Rectifier from Gaohui Rectifier provides 2000A at 30V. This Air Cooled Special Purpose Electro-Descaling Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Special Purpose Electro-Descaling Rectifier suits electro-descaling cells and electrode banks.
Cells in electro-descaling lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady scale removal. In practice, a plant treating cooling water circuits around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–2000A adjustable |
| DC Output Voltage | 0–30V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-descaling cells |
| Typical Application | Electro-Descaling |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Heavy Output Electrocoagulation Rectifier from Gaohui Rectifier delivers 2000A at 30V. Engineers choose this Air Cooled Heavy Output Electrocoagulation Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Heavy Output Electrocoagulation Rectifier pairs naturally with electrocoagulation cell stacks.
For example, metal finishing shops rely on electrocoagulation to strip oils from rinse water. The rectifier feeds the cell bank with a flat current so flocs form evenly across every plate. In practice, a job shop processes several batches each shift. Therefore, operators return to the same setpoint after each batch. Hence, effluent quality stays within permit limits.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–2000A adjustable |
| DC Output Voltage | 0–30V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Periodic Reversing Rectifier outputs 2000A at 60V. Plant operators rely on this Air Cooled Periodic Reversing Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Periodic Reversing Rectifier fits periodic reversal lines from pilot to production.
Besides, chlor-alkali and hypochlorite cells foul with calcium and magnesium deposits. Periodic reversal keeps the electrode surface active without acid wash. In practice, a water plant runs reversal every few hours. Consequently, chlorine strength stays consistent month to month. Therefore, operators never shut down for cell cleaning.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–2000A adjustable |
| DC Output Voltage | 0–60V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Mega Current Electrocoagulation Rectifier from Gaohui Rectifier provides 2500A at 12V. This Air Cooled Mega Current Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Mega Current Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–2500A adjustable |
| DC Output Voltage | 0–12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Electro-Catalytic Oxidation Driver Rectifier from Gaohui Rectifier delivers 3000A at 12V. Engineers choose this Air Cooled Electro-Catalytic Oxidation Driver Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Electro-Catalytic Oxidation Driver Rectifier pairs naturally with electro-catalytic oxidation cell stacks.
For instance, chemical plants treat spent solvent rinse water through DSA anode cells. The rectifier supplies a steady DC so hydroxyl radicals form at a constant rate. In practice, a batch reactor runs several cycles per day. Hence, operators dial in a fixed current that matches the organic load. Thus, COD drops predictably batch after batch.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–3000A adjustable |
| DC Output Voltage | 0–12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled High Power Electro-Catalytic Rectifier outputs 3000A at 15V. Plant operators rely on this Air Cooled High Power Electro-Catalytic Rectifier to keep treatment current flat all day. Therefore, the Air Cooled High Power Electro-Catalytic Rectifier fits electro-catalytic lines from pilot to production.
Moreover, pulp and paper mills use catalytic treatment to remove color from bleach plant effluent. The rectifier holds voltage steady across the electrode array. In practice, a mill runs its paper machine 24 hours a day. Consequently, operators tune current once after start-up. Thus, discharge color stays below regulatory limits year round.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–3000A adjustable |
| DC Output Voltage | 0–15V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Industrial Electrocoagulation Rectifier from Gaohui Rectifier provides 3000A at 18V. This Air Cooled Industrial Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled Industrial Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–3000A adjustable |
| DC Output Voltage | 0–18V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled N+1 Parallel Electrocoagulation Rectifier from Gaohui Rectifier delivers 4000A at 24V. Engineers choose this Air Cooled N+1 Parallel Electrocoagulation Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled N+1 Parallel Electrocoagulation Rectifier pairs naturally with electrocoagulation cell stacks.
For example, metal finishing shops rely on electrocoagulation to strip oils from rinse water. The rectifier feeds the cell bank with a flat current so flocs form evenly across every plate. In practice, a job shop processes several batches each shift. Therefore, operators return to the same setpoint after each batch. Hence, effluent quality stays within permit limits.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–4000A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled Super Duty Electro-Catalytic Rectifier outputs 4000A at 24V. Plant operators rely on this Air Cooled Super Duty Electro-Catalytic Rectifier to keep treatment current flat all day. Therefore, the Air Cooled Super Duty Electro-Catalytic Rectifier fits electro-catalytic lines from pilot to production.
Moreover, pulp and paper mills use catalytic treatment to remove color from bleach plant effluent. The rectifier holds voltage steady across the electrode array. In practice, a mill runs its paper machine 24 hours a day. Consequently, operators tune current once after start-up. Thus, discharge color stays below regulatory limits year round.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–4000A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The N+1 Parallel Electro-Catalytic Rectifier from Gaohui Rectifier provides 4500A at 15V. This N+1 Parallel Electro-Catalytic Rectifier holds cell current steady through long shifts. Furthermore, the N+1 Parallel Electro-Catalytic Rectifier suits electro-catalytic cells and electrode banks.
Cells in electro-catalytic treatment lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady reaction control. In practice, a plant treating industrial effluent around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–4500A adjustable |
| DC Output Voltage | 0–15V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Maximum Periodic Reversal Rectifier from Gaohui Rectifier delivers 5000A at 10V. Engineers choose this Air Cooled Maximum Periodic Reversal Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Maximum Periodic Reversal Rectifier pairs naturally with periodic reversal cell stacks.
For example, electrowinning plants reverse polarity to strip cathode deposits automatically. The rectifier toggles direction on a set schedule so no manual scraping is needed. In practice, a refinery runs 15 minute cycles around the clock. Hence, operators recover metal without stopping the line. Thus, labor cost drops and uptime rises.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–5000A adjustable |
| DC Output Voltage | 0–10V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Water Cooled N+1 Parallel Electro-Catalytic Oxidation Rectifier outputs 9000A at 24V. Plant operators rely on this Water Cooled N+1 Parallel Electro-Catalytic Oxidation Rectifier to keep treatment current flat all day. Therefore, the Water Cooled N+1 Parallel Electro-Catalytic Oxidation Rectifier fits electro-catalytic oxidation lines from pilot to production.
Besides, landfill leachate treatment plants use oxidation cells to break down recalcitrant COD. The rectifier holds output flat despite swings in feed strength. In practice, leachate quality varies with weather and season. Therefore, operators tune current once and let the rectifier hold it. Consequently, downstream polishing loads stay manageable.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–9000A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Water cooled |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled High Voltage Electrocoagulation Rectifier from Gaohui Rectifier provides 30A at 500V. This Air Cooled High Voltage Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled High Voltage Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–30A adjustable |
| DC Output Voltage | 0–500V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Low Voltage Electro-Catalytic Rectifier from Gaohui Rectifier delivers 100A at 6V. Engineers choose this Low Voltage Electro-Catalytic Rectifier when dosing repeatability matters across shifts. Moreover, the Low Voltage Electro-Catalytic Rectifier pairs naturally with electro-catalytic cell stacks.
For instance, pharmaceutical plants treat process wastewater through catalytic oxidation cells. The rectifier supplies a flat current so pharmaceutical residues break down completely. In practice, a batch plant generates variable effluent throughout the day. Therefore, operators leave the rectifier on a fixed setpoint. Hence, the municipal sewer sees consistent COD loads.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–6V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Compact Electro-Catalytic Oxidation Rectifier outputs 100A at 12V. Plant operators rely on this Compact Electro-Catalytic Oxidation Rectifier to keep treatment current flat all day. Therefore, the Compact Electro-Catalytic Oxidation Rectifier fits electro-catalytic oxidation lines from pilot to production.
Besides, landfill leachate treatment plants use oxidation cells to break down recalcitrant COD. The rectifier holds output flat despite swings in feed strength. In practice, leachate quality varies with weather and season. Therefore, operators tune current once and let the rectifier hold it. Consequently, downstream polishing loads stay manageable.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Small Scale Electrocoagulation Rectifier from Gaohui Rectifier provides 100A at 12V. This Small Scale Electrocoagulation Rectifier holds cell current steady through long shifts. Furthermore, the Small Scale Electrocoagulation Rectifier suits electrocoagulation cells and electrode banks.
Cells in water treatment electrocoagulation lines run for hours at a time. Consequently, the rectifier holds the current inside a narrow band for consistent floc formation. In practice, a plant running a coagulation cell line around the clock. Hence, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–100A adjustable |
| DC Output Voltage | 0–12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Medium Output Sodium Hypochlorite Rectifier from Gaohui Rectifier delivers 175A at 24V. Engineers choose this Medium Output Sodium Hypochlorite Rectifier when dosing repeatability matters across shifts. Moreover, the Medium Output Sodium Hypochlorite Rectifier pairs naturally with sodium hypochlorite cell stacks.
For example, municipal water plants generate dilute hypochlorite on site instead of delivering chlorine gas. The rectifier drives brine electrolysis cells at a constant current. In practice, a treatment plant doses disinfection around the clock. Therefore, operators adjust output to match demand curves. As a result, chemical delivery trucks stop coming weekly.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–175A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the High Voltage Electro-Catalytic Oxidation Rectifier outputs 250A at 120V. Plant operators rely on this High Voltage Electro-Catalytic Oxidation Rectifier to keep treatment current flat all day. Therefore, the High Voltage Electro-Catalytic Oxidation Rectifier fits electro-catalytic oxidation lines from pilot to production.
Besides, landfill leachate treatment plants use oxidation cells to break down recalcitrant COD. The rectifier holds output flat despite swings in feed strength. In practice, leachate quality varies with weather and season. Therefore, operators tune current once and let the rectifier hold it. Consequently, downstream polishing loads stay manageable.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–250A adjustable |
| DC Output Voltage | 0–120V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Automatic Reversal Electro-Catalytic Rectifier from Gaohui Rectifier provides 250A at 120V. This Automatic Reversal Electro-Catalytic Rectifier holds cell current steady through long shifts. Furthermore, the Automatic Reversal Electro-Catalytic Rectifier suits electro-catalytic cells and electrode banks.
Cells in electro-catalytic treatment lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady reaction control. In practice, a plant treating industrial effluent around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–250A adjustable |
| DC Output Voltage | 0–120V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Automatic Reversal Rectifier from Gaohui Rectifier delivers 250A at 150V. Engineers choose this Automatic Reversal Rectifier when dosing repeatability matters across shifts. Moreover, the Automatic Reversal Rectifier pairs naturally with periodic reversal cell stacks.
For example, electrowinning plants reverse polarity to strip cathode deposits automatically. The rectifier toggles direction on a set schedule so no manual scraping is needed. In practice, a refinery runs 15 minute cycles around the clock. Hence, operators recover metal without stopping the line. Thus, labor cost drops and uptime rises.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–250A adjustable |
| DC Output Voltage | 0–150V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the High Voltage Electro-Catalytic Rectifier outputs 250A at 300V. Plant operators rely on this High Voltage Electro-Catalytic Rectifier to keep treatment current flat all day. Therefore, the High Voltage Electro-Catalytic Rectifier fits electro-catalytic lines from pilot to production.
Moreover, pulp and paper mills use catalytic treatment to remove color from bleach plant effluent. The rectifier holds voltage steady across the electrode array. In practice, a mill runs its paper machine 24 hours a day. Consequently, operators tune current once after start-up. Thus, discharge color stays below regulatory limits year round.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–250A adjustable |
| DC Output Voltage | 0–300V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Medium Power Electro-Catalytic Rectifier from Gaohui Rectifier provides 300A at 12V. This Medium Power Electro-Catalytic Rectifier holds cell current steady through long shifts. Furthermore, the Medium Power Electro-Catalytic Rectifier suits electro-catalytic cells and electrode banks.
Cells in electro-catalytic treatment lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady reaction control. In practice, a plant treating industrial effluent around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–300A adjustable |
| DC Output Voltage | 0–12V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The High Output Sodium Hypochlorite Rectifier from Gaohui Rectifier delivers 300A at 30V. Engineers choose this High Output Sodium Hypochlorite Rectifier when dosing repeatability matters across shifts. Moreover, the High Output Sodium Hypochlorite Rectifier pairs naturally with sodium hypochlorite cell stacks.
For example, municipal water plants generate dilute hypochlorite on site instead of delivering chlorine gas. The rectifier drives brine electrolysis cells at a constant current. In practice, a treatment plant doses disinfection around the clock. Therefore, operators adjust output to match demand curves. As a result, chemical delivery trucks stop coming weekly.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–300A adjustable |
| DC Output Voltage | 0–30V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for sodium hypochlorite cells |
| Typical Application | Sodium Hypochlorite Cells |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the 3D Electro-Catalytic Rectifier outputs 300A at 40V. Plant operators rely on this 3D Electro-Catalytic Rectifier to keep treatment current flat all day. Therefore, the 3D Electro-Catalytic Rectifier fits electro-catalytic lines from pilot to production.
Moreover, pulp and paper mills use catalytic treatment to remove color from bleach plant effluent. The rectifier holds voltage steady across the electrode array. In practice, a mill runs its paper machine 24 hours a day. Consequently, operators tune current once after start-up. Thus, discharge color stays below regulatory limits year round.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–300A adjustable |
| DC Output Voltage | 0–40V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Industrial Electro-Catalytic Rectifier from Gaohui Rectifier provides 500A at 24V. This Industrial Electro-Catalytic Rectifier holds cell current steady through long shifts. Furthermore, the Industrial Electro-Catalytic Rectifier suits electro-catalytic cells and electrode banks.
Cells in electro-catalytic treatment lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady reaction control. In practice, a plant treating industrial effluent around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–24V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Periodic Reversal Electro-Catalytic Rectifier from Gaohui Rectifier delivers 500A at 30V. Engineers choose this Air Cooled Periodic Reversal Electro-Catalytic Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Periodic Reversal Electro-Catalytic Rectifier pairs naturally with electro-catalytic cell stacks.
For instance, pharmaceutical plants treat process wastewater through catalytic oxidation cells. The rectifier supplies a flat current so pharmaceutical residues break down completely. In practice, a batch plant generates variable effluent throughout the day. Therefore, operators leave the rectifier on a fixed setpoint. Hence, the municipal sewer sees consistent COD loads.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–30V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Periodic Reversal Electrochemical DC Rectifier outputs 500A at 36V. Plant operators rely on this Periodic Reversal Electrochemical DC Rectifier to keep treatment current flat all day. Therefore, the Periodic Reversal Electrochemical DC Rectifier fits periodic reversal lines from pilot to production.
Besides, chlor-alkali and hypochlorite cells foul with calcium and magnesium deposits. Periodic reversal keeps the electrode surface active without acid wash. In practice, a water plant runs reversal every few hours. Consequently, chlorine strength stays consistent month to month. Therefore, operators never shut down for cell cleaning.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–36V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Automatic periodic polarity reversal |
| Typical Application | Periodic Reversal Electrolysis |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled High Voltage Electro-Catalytic Oxidation Rectifier from Gaohui Rectifier provides 500A at 50V. This Air Cooled High Voltage Electro-Catalytic Oxidation Rectifier holds cell current steady through long shifts. Furthermore, the Air Cooled High Voltage Electro-Catalytic Oxidation Rectifier suits electro-catalytic oxidation cells and electrode banks.
Cells in electro-catalytic oxidation lines run for hours at a time. Therefore, the rectifier holds the current inside a narrow band for complete pollutant breakdown. In practice, a plant treating refractory organics around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In addition, the rectifier offers a multi-step timer with up to eight segments. Each segment sets its own current, voltage and hold time. As a result, unattended recipes run from start to finish without manual tweaks. Thus, a single operator can supervise several cells at once. Therefore, batch dosing stays consistent across the whole shift.
| Parameter | Value |
|---|---|
| DC Output Current | 0–500A adjustable |
| DC Output Voltage | 0–50V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Continuous Electro-Catalytic Rectifier from Gaohui Rectifier delivers 600A at 30V. Engineers choose this Air Cooled Continuous Electro-Catalytic Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Continuous Electro-Catalytic Rectifier pairs naturally with electro-catalytic cell stacks.
For instance, pharmaceutical plants treat process wastewater through catalytic oxidation cells. The rectifier supplies a flat current so pharmaceutical residues break down completely. In practice, a batch plant generates variable effluent throughout the day. Therefore, operators leave the rectifier on a fixed setpoint. Hence, the municipal sewer sees consistent COD loads.
Furthermore, RS485 communication links the rectifier to the plant SCADA system. Operators read current, voltage and fault codes from the control room. In addition, the same bus lets engineers tune setpoints remotely. Hence, on-site visits drop to scheduled maintenance only. Consequently, the whole treatment line stays under central monitoring.
| Parameter | Value |
|---|---|
| DC Output Current | 0–600A adjustable |
| DC Output Voltage | 0–30V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
Built by Gaohui Rectifier, the Air Cooled High Output Electro-Catalytic Oxidation Rectifier outputs 800A at 30V. Plant operators rely on this Air Cooled High Output Electro-Catalytic Oxidation Rectifier to keep treatment current flat all day. Therefore, the Air Cooled High Output Electro-Catalytic Oxidation Rectifier fits electro-catalytic oxidation lines from pilot to production.
Besides, landfill leachate treatment plants use oxidation cells to break down recalcitrant COD. The rectifier holds output flat despite swings in feed strength. In practice, leachate quality varies with weather and season. Therefore, operators tune current once and let the rectifier hold it. Consequently, downstream polishing loads stay manageable.
Besides, IGBT switching keeps ripple well below five percent RMS. Tight ripple protects sensitive electrodes and improves treatment uniformity. Moreover, forced air cooling keeps cabinet temperatures low in warm plants. Consequently, the rectifier holds rated current continuously without derating. Therefore, operators plan long campaigns with confidence.
| Parameter | Value |
|---|---|
| DC Output Current | 0–800A adjustable |
| DC Output Voltage | 0–30V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic oxidation cells |
| Typical Application | Electro-Catalytic Oxidation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Dedicated Electro-Catalytic Rectifier from Gaohui Rectifier provides 1300A at 26V. This Dedicated Electro-Catalytic Rectifier holds cell current steady through long shifts. Furthermore, the Dedicated Electro-Catalytic Rectifier suits electro-catalytic cells and electrode banks.
Cells in electro-catalytic treatment lines run for hours at a time. Furthermore, the rectifier holds the current inside a narrow band for steady reaction control. In practice, a plant treating industrial effluent around the clock. Consequently, operators repeat the same setting from the first cell to the last. Operators set a current limit below rated output for lighter dosing.
In case of a fault, the rectifier trips on overcurrent, overvoltage or over temperature. A visible alarm on the panel pinpoints the cause immediately. Furthermore, the internal logger records the last twenty events. Therefore, troubleshooting is fast and predictable for the maintenance crew. Hence, unexpected downtime stays short across the plant.
| Parameter | Value |
|---|---|
| DC Output Current | 0–1300A adjustable |
| DC Output Voltage | 0–26V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | To be confirmed |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electro-catalytic cells |
| Typical Application | Electro-Catalytic Treatment |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |
The Air Cooled Process Electrocoagulation Rectifier from Gaohui Rectifier delivers 2000A at 20V. Engineers choose this Air Cooled Process Electrocoagulation Rectifier when dosing repeatability matters across shifts. Moreover, the Air Cooled Process Electrocoagulation Rectifier pairs naturally with electrocoagulation cell stacks.
For example, metal finishing shops rely on electrocoagulation to strip oils from rinse water. The rectifier feeds the cell bank with a flat current so flocs form evenly across every plate. In practice, a job shop processes several batches each shift. Therefore, operators return to the same setpoint after each batch. Hence, effluent quality stays within permit limits.
Moreover, the rectifier runs in constant current or constant voltage mode. Operators program a smooth ramp so the cell reaches target current without a spike. Consequently, the treatment cell receives a consistent supply from the first second. Furthermore, the front panel displays output current, output voltage and alarm status in real time. As a result, operators adjust settings without opening the cabinet.
| Parameter | Value |
|---|---|
| DC Output Current | 0–2000A adjustable |
| DC Output Voltage | 0–20V adjustable |
| AC Input Voltage | AC 380V ±10%, three phase |
| Cooling Method | Forced air |
| Ripple Factor | ≤5% RMS |
| Control Mode | IGBT/PWM, constant current and constant voltage |
| Communication | RS485 |
| Special Feature | Stable DC for electrocoagulation cells |
| Typical Application | Water Treatment Electrocoagulation |
| Dimensions | To be confirmed on order |
| Weight | To be confirmed on order |
| Specifications subject to change. Custom designs available upon request. | |